SIGNAL Instruments USA Microprocessor Control

Advanced Gas Analyzers

2-Year Warranty
Applications Gases Technologies
Series 4 Solar
Solar flame ionization detection (FID) comprise a range of rack mounted and portable FIDs for accurate, reliable measurement of Methane (CH4) only, Non-Methane (NMHC) & Total (THC) Hydrocarbons, and Volatile Organic Compounds (VOCs).


The Signal Solar Flame Ionization Detector product line is unique in the market with its precision machined, monobloc arrangement of ceramic isolated flame jet tip cylindrical collector and venturi effect air/fuel/sample design. This has produced reproducibility of production so that every analyzer has exactly the same characteristics. The need for this uniformity is important when measuring hydrocarbons as there are many different species in the measurement mix and barometric changes can be a problem. The monobloc design encompasses the hot oven, the heated filter, span/zero/cal valve and the optional heated sample pump. Thus, a very compact and leak proof design is provided. The sample pump uses a brushless DC motor and polytetrafluoroethylene (PTFE) coated diaphragm for total reliability and ease of maintenance.

We offer a heated 191C single FID for total hydrocarbon, a Methane-only single FID using a catalytic cutter to remove/convert all hydrocarbons except Methane, and a dual detector for continuous total hydrocarbons (THC), Methane (CH4) and non-methane (NMHC). We also offer a low cost, low temperature version for samples with low sample dew points.

Signal flame ionization analyzers (FIA) comply with the following certifications: QUAL1 BS EN 12619:2013 and USA-EPA 40 Code of Federal Regulations (CFR) Part 60 Method 25 & Part 503 Applications.

Measurement technique(s):

  • Flame ionization (FIA / FID)

Gas(es) measured:

  • Methane (CH4) only
  • Non-Methane Hydrocarbons (NMHC)
  • Total Hydrocarbons (THC)
  • Volatile Organic Compounds (VOCs)

Solar Features:

Applications:

  • Automotive exhaust emissions
  • Combustion analysis
  • Continuous Emissions Monitoring Systems (CEMS)
  • Environmental compliance
  • Gas purity
  • Gas turbine emissions
  • OEM system integration
  • Process monitoring
  • Research

Solar Options:

  • Air purifier - internal catalytic (AS90) = Air supplied to units must be clean & zero-grade to avoid an offset & instability in readings; the AS90 is a heated catalytic type cleanup system for appropriately clean air as an alternative to using synthetic bottled air.
  • Highest full-scale measurement = 10% (as methane) for non-cutter FIA / 4% as methane for FIA fitted with a cutter.
  • Moisture filter = Remove excess moisture to protect the longevity of an analyzer; recommended for saturated samples.
  • Pump for air - external = Provides FID-flame (burner) & zero calibration air supplies.
  • Pump for air - Internal = Provides FID-flame (burner) & zero calibration air supplies.
  • Pump for sample - external = Used when sample is not under positive pressure.
  • Pump for sample - internal = Used when sample is not under positive pressure.
  • Pure hydrogen fuel (in lieu of H2/He helifuel, which is better to minimize the effect of oxygen synergism & for combustion applications ) fuel = Reduces operating costs.
  • Series 4 Options for all Classes (Aurora, Pulsar, Quasar, Solar)
Configurations
measurement channels
model detectors cutter oven temp CH4-only NMHC THC
Cold FID based analyzers
CFID-CH4 1 yes cold 1 0 0
CFID-DTHC 2 no cold 0 0 2
CFID-NMHC 1 switched cold 1 1 1
CFID-THC 1 no cold 0 0 1
Heated FID based analyzers
HFID-CH4 1 yes hot 1 0 0
HFID-DNMHC 2 yes hot 1 1 1
HFID-NMHC 1 switched hot 1 1 1
HFID-THC 1 no hot 0 0 1

Technical Specification
Data Sheet
Operating Manual

We offer any combination of analyzers built into 19" rack sampling systems for your application. If your requirements are not in our standard product range, contact us about our customized system solutions.

Portable models 3010 MiniFID Pure and (standard) 3010 MiniFID are also available for THC analysis. Legacy Series III Models 3000MO (CH4-only) and 3000HM (THC) remain available.


SIGNAL USA
355 North York Rd.
Willow Grove, PA 19090
Tel: 215.830.8882
Fax: 215.830.8922
Toll free: 866.SIGNAL.U
Hours of operation:
M-F 8AM to 6PM Eastern Time
weekends and 24-hour emergency service by agreement
email: sales@k2bw.com
© SIGNAL USA. All rights reserved.

continuous emission monitoring system design, manufacture, applications engineering, supplies and service